Evaluation of marginal fit of conventional, milled, and direct metal laser sintered cobalt chromium crowns: A comparative study

Authors

  • J Sharan Bihar Sharif, Bihar, India
  • GK Chauhan Oxford Dental College and Hospital Bengaluru, Karnataka, India
  • S Munireddy Maaruti College of Dental Sciences & Research Centre, Bengaluru, Karnataka, India
  • S Srinivas Bengaluru, Karnataka, India
  • P Sinha Hi-Tech Dental College and Hospital, Bhubaneswar, Odisha, India
  • S KC Basnyat Kathmandu University School of Medical Sciences, Panauti, Nepal
  • J Sharan All India Institute of Medical Sciences, Bhubaneswar, Odisha, India

DOI:

https://doi.org/10.3126/jnprossoc.v7i1.70455

Keywords:

Buccal fit, Cobalt-chromium crown, Computer-aided design and manufacturing, Direct metal laser sintering, Marginal fit, Occlusal fit

Abstract

Introduction: A close marginal adaptation of a fixed partial denture is crucial for its long-term functionality without any adversity. Human errors and casting defects are common with conventional techniques. The latest techniques, direct metal laser sintering (DMLS), and computer-aided design and manufacturing (CAD/CAM) tend to overcome these errors.

Methods: 33 dies were fabricated from similar number of impressions of a tooth based on standardized measurement and were equally distributed in 3 groups (11 each). Crowns were fabricated using conventional, DMLS, and CAD/CAM methods using chrome-cobalt. All the fabricated crowns were cemented onto the die using resin cement and 50 N force, followed by leaving them for 12 hours at room temperature. Then, each crown was sectioned into two halves, and a stereomicroscope was used to evaluate the cement thickness at three different reference points.

Results: The marginal fit of conventionally fabricated crowns, DMLS, and CAD/CAM crowns were in the clinically acceptable range. Marginal discrepancy remained more in conventionally fabricated crowns than in CAD/CAM and DMLS crowns. However, the axial discrepancy in crowns fabricated by the conventional method was lesser than in CAD/CAM and DMLS fabricated crowns. The occlusal discrepancy in DMLS-fabricated crowns was more than that of the other two methods.

Conclusion: The DMLS group displayed better marginal accuracy with respect to the marginal reference point. On the other hand, the convention group exhibited superior adaptability when the buccal and occlusal reference points were considered. Similarly, statistically significant results were observed when the conventional group's 'margin reference point' was compared with the CAD/CAM or DMLS group. The margin reference point of the CAD/CAM group was comparable with DMLS cobalt-chromium crowns.

Downloads

Download data is not yet available.
Abstract
89
PDF
39

Author Biographies

J Sharan, Bihar Sharif, Bihar, India

Consultant Prosthodontist

GK Chauhan, Oxford Dental College and Hospital Bengaluru, Karnataka, India

Department of Prosthodontics

S Munireddy, Maaruti College of Dental Sciences & Research Centre, Bengaluru, Karnataka, India

Department of Prosthodontics, AECS

S Srinivas, Bengaluru, Karnataka, India

Consultant Prosthodontist

P Sinha, Hi-Tech Dental College and Hospital, Bhubaneswar, Odisha, India

Department of Prosthodontics

S KC Basnyat, Kathmandu University School of Medical Sciences, Panauti, Nepal

Department of Prosthodontics

J Sharan, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India

Department of Dentistry

Downloads

Published

2024-10-04

How to Cite

Sharan, J., Chauhan, G., Munireddy, S., Srinivas, S., Sinha, P., Basnyat, S. K., & Sharan, J. (2024). Evaluation of marginal fit of conventional, milled, and direct metal laser sintered cobalt chromium crowns: A comparative study. Journal of Nepalese Prosthodontic Society, 7(1), 14–23. https://doi.org/10.3126/jnprossoc.v7i1.70455

Issue

Section

Original Articles