Comparison of Foundation by Direct Shear Test in Different Soil Condition

Authors

  • Kushal Jung K.C. Department of Civil Engineering, Kantipur Engineering College, Dhapakhel, Nepal
  • Peshal Poudel Department of Civil Engineering, Kantipur Engineering College, Dhapakhel, Nepal
  • Niraj Lamichhane Department of Civil Engineering, Kantipur Engineering College, Dhapakhel, Nepal
  • Jeewan Bhat Department of Civil Engineering, Kantipur Engineering College, Dhapakhel, Nepal
  • Prasang Sharma Department of Civil Engineering, Kantipur Engineering College, Dhapakhel, Nepal

DOI:

https://doi.org/10.3126/injet.v1i2.66707

Keywords:

Foundation engineering, direct shear test, shear strength parameters, bearing capacity

Abstract

In this paper, we mainly focused on the comparison of foundation in two different locations. Size of foundation depends on bearing capacity of soil. Standard proctor test has been conducted to determine Optimum Moisture Content (OMC) of soil and Direct shear test has been conducted to determine the shear strength parameters in OMC. Bearing capacity of soil is calculated from shear strength parameters using Terzaghi’s equation. Area of foundation is calculated and it is found that area differ by 34.47% at two locations.  

Downloads

Download data is not yet available.
Abstract
219
PDF
87

Downloads

Published

2024-06-24

How to Cite

Jung K.C., K., Poudel, P., Lamichhane, N., Bhat, J., & Sharma, P. (2024). Comparison of Foundation by Direct Shear Test in Different Soil Condition. International Journal on Engineering Technology, 1(2), 296–301. https://doi.org/10.3126/injet.v1i2.66707