Successful repair of Aortic Rupture in a patient with bicuspid aortic valve after Aortic Valve Replacement: a rare case
DOI:
https://doi.org/10.3126/njh.v17i1.28813Keywords:
acute aortic rupture, bicuspid aortic valve, post aortic valve replacementAbstract
The occurrence of acute aortic rupture after aortic valve replacement is unusual; but catastrophic. We report a case of a 71-year-old gentleman with a bicuspid aortic valve who developed acute aortic rupture after an elective bioprosthetic aortic valve replacement surgery in which successful repair was carried out with the preservation of the prosthetic valve.