Functional outcome of the treatment of AO-ASIF type C distal humerus fracture using Lambda plate

Authors

  • Krishna Bahadur Bista Gandaki Medical College Teaching Hospital, Nepal https://orcid.org/0000-0002-9596-6435
  • Rabeendra Prasad Shrestha Gandaki Medical College Teaching Hospital, Nepal
  • Bhola Shrestha Gandaki Medical College Teaching Hospital, Nepal
  • Ishwar Sharma Kandel Gandaki Medical College Teaching Hospital, Nepal
  • Rabi Mohan Dakal Gandaki Medical College Teaching Hospital, Nepal

DOI:

https://doi.org/10.3126/jgmcn.v13i2.31933

Keywords:

Lambda plate, Distal humerus, Fracture

Abstract

Introduction: Although the use of two plates for the treatment of type-C distal humerus fracture is popular, site of plate placement still is under debate. Use of Lambda plate for the fracture treatment can be easier and settle the dispute. This study aims to evaluate the functional outcome of the surgery using Lambda Plate. This can be a reference for surgeons and helps them make the decision about choice of implant for type C distal humerus fracture treatment among Nepalese people.

Methods: This interventional study used Lambda plate for the treatment of type C fracture of distal humerus. Patients were examined at 4, 12, and 24 weeks respectively for the measurement of the outcome. Visual analogous scale was used for assessment of pain, range of motion for functional recovery and Mayo Elbow Performance Score was used for the assessment of functional outcome. Paired-samples t-test and linear regression was used to for data analysis.

Results: Functional outcome at the last follow-up was excellent in 24(53.33%) patients, good in 18(40%) patients and fair in 3(6.67%) patients. Range of motion of elbow increased significantly with every follow-up (p-value <0.001). Average angle of flexion at last follow-up was 117.53°±11.74 while loss of extension was 7.53°±4.86. Average number of patients had their fracture union at 19.84±2.38 weeks. There was no association of age, sex and union weeks with functional outcome when measured with MEPS.

Conclusion: Fixation of distal humerus fracture by using Lambda plate gave excellent and satisfying outcome in terms of pain, range of motion and objective functional outcome.  

Downloads

Download data is not yet available.
Abstract
278
PDF
402

Author Biographies

Krishna Bahadur Bista, Gandaki Medical College Teaching Hospital, Nepal

Department of Orthopedics

Rabeendra Prasad Shrestha, Gandaki Medical College Teaching Hospital, Nepal

Department of Orthopedics

Bhola Shrestha, Gandaki Medical College Teaching Hospital, Nepal

Department of Orthopedics

Ishwar Sharma Kandel, Gandaki Medical College Teaching Hospital, Nepal

Department of Orthopedics

Rabi Mohan Dakal, Gandaki Medical College Teaching Hospital, Nepal

Department of Orthopedics

Downloads

Published

2020-12-25

How to Cite

Bista, K. B., Shrestha, R. P., Shrestha, B., Kandel, I. S., & Dakal, R. M. (2020). Functional outcome of the treatment of AO-ASIF type C distal humerus fracture using Lambda plate. Journal of Gandaki Medical College-Nepal, 13(2), 128–133. https://doi.org/10.3126/jgmcn.v13i2.31933

Issue

Section

Original Articles